ATMTERM

Heat that does not
depend on fuel.

ATP-TermaRON turns 1 kWh of electricity into 3 kWh of heat. No gas, boiler room or complex approvals.

✦Scales from a private home to an industrial complex

ATMTERM
THERMAL
GENERATOR
01 / 03
3.0COP · kWh heat from 1 kWh
10 kW — 10 MWpower range
36 mo.first-loop warranty

01 / Technology

One module
replaces a boiler room.

In ATM-TERM, an electric impulse triggers hydrolysis, cavitation and resonant excitation of water molecules and heats the primary-loop coolant. Automation holds the mode using supply, return and air sensors, and the heat passes into the building system through a heat exchanger.

01

Molecular reactor

Generates heat and holds the mode via supply, return and air sensors.

+
02

Primary loop

A heat exchanger transfers energy to the building system without mixing fluids.

+
03

Smart controls

ZONT GSM / Wi-Fi lets you monitor the system from your phone.

+
ATM-TERM
  • Hydrolysis
  • Cavitation
  • Resonance

Module cross-section

What a module
is made of.

A cross-section of the module. Tap a point to see each unit: the reactor shows the processes an electric impulse starts.

  1. 01
    Thermal reactorHeats the primary-loop coolant; the mode is held by sensors.
  2. 02
    Plate heat exchangerPasses heat to the building loop with no mixing of media.
  3. 03
    Control unitMode indication and module control; from a smartphone via ZONT GSM / Wi-Fi.
  4. 04
    Piping and sensorsFirst-loop piping, pressure gauge and shut-off valves: pressure and temperature under control.

02 / Product line

Three modules.
Any scale.

02
MODELTHERMAL POWERAREA
01ATM-TERM / 1F10–16 kWup to 100 m²↗
02ATM-TERM / 2F20–32 kW100–300 m²↗
03ATM-TERM / 3F30–100 kW300–1,000 m²↗

Modules cascade into one thermal hub — from 10 kW to 10 MW.

Applications

Where is
TermaRON used?

From private homes to industrial plants — one principle, with modular capacity sized to the task.

  • 01
    Private houses and cottages

    Autonomous heating for houses, dachas and townhouses. No coal or firewood.

  • 02
    Apartment buildings

    A solution for utilities and management companies. New builds with per-flat heating.

  • 03
    Hotels, restaurants, malls, pools

    Commercial property with high reliability requirements.

  • 04
    Workshops and warehouses

    Heating for hangars and production halls. Modules can be combined.

  • 05
    Special safety requirements

    Car services, garages, fuel depots — anywhere open flame is not allowed.

  • 06
    Greenhouses and agriculture

    Climate control for greenhouses, farms and poultry houses. No exhaust, which plants need.

  • 07
    Sports facilities

    Sports complexes, fitness clubs and out-of-town sports bases.

  • 08
    Cultural and religious sites

    Temples, churches, mosques, synagogues and other heritage buildings.

  • 09
    Temporary sites

    Construction camps, mobile field points, seasonal campsites and glamping.

03 / How it works

Heat travels
through four nodes.

ATP-TermaRON sits inside the building loop: the grid powers the reactor, then heat is distributed to the zones that need it.

Controlscontrol and sensors 220 / 380 VGrid 1 kWh3 kWh R1Reactor T1Heat exchanger G1Hydraulic separator K1Collector RadiatorsHot waterUnderfloor Primary loop Building loop Return Controlscontrol and sensors 220 / 380 VGrid 1 kWh3 kWh R1Reactor T1Heat exchanger G1Hydraulic separator K1Collector RadiatorsHot waterUnderfloor Primary loop Building loop Return
ElectricityHeat supplyReturn

Thermal point diagram · simplified animation of energy flows

04 / Completed projects

Solutions that
already work.

Real TermaRON sites: area, system composition and resulting running costs.

04
Apartments, KaliningradResidential

Apartments

Kaliningrad

Area
1,700 m²
Solution
2 TermaRON modules (19 kWh consumption per module)
Savings
Monthly electricity cost — only 93,150 ₽
Result
Stable heating and hot water for the whole building at low running costs
Shopping mall, DarnaCommercial

Shopping mall

Darna

Area
1,700 m²
Solution
2 TermaRON modules (19 kWh consumption per module)
Savings
Consumption — 20,289 kWh/month, cost — 112,806 ₽
Result
Even heating of a large retail space with a significant cut in energy costs
Hotel “Green Palace”, VnukovoHospitality

Hotel “Green Palace”

Vnukovo

Area
10,080 m³, 68 rooms
Solution
2 TermaRON modules (311 kW load)
Savings
Cost — 252,700 ₽/month instead of diesel fuel costs
Result
60% cost reduction, stable heat and hot water with no fuel logistics
04Extreme climate

Filling station No. 51

Yakutsk

Area
250 m²
Solution
1 TermaRON module (18 kWh consumption per hour)
Savings
Energy use 3× lower than the calculated heat loss
Result
Performance confirmed at temperatures down to −43.6 °C
05Industrial

Industrial base

Simferopol

Area
6,000 m²
Solution
6 TermaRON modules, 100 kW each
Savings
Project cost — 3 M ₽ instead of 13 M ₽ for a gas boiler house
Result
Upgrade completed in 2 months with minimal running costs
06Agriculture

Greenhouse

Moscow region

Area
1,000 m²
Solution
5 TermaRON modules, 100 kW each
Savings
500 kW total with only 150 kW of allocated electrical capacity
Result
450 kW heat load fully covered at minimal consumption
07Retail

Pyaterochka store

Komsomolsk-on-Amur

Area
450 m²
Solution
1 TermaRON module (15 kW consumption)
08Sport

Sports complex

Tyumen

Area
2,000 m²
Solution
2 TermaRON modules (15 kW consumption)
Savings
Cost — 150,000 ₽
09Commercial

Shopping mall

Moscow, Rublyovskoye hwy

Area
2,500 m²
Solution
2 TermaRON modules for heating and hot water (30 kW consumption)
Savings
Cost — 216,000 ₽

Want the same? Send your site parameters and we will prepare a solution and calculation for your region.

Data from completed TermaRON projects. Costs for your site are calculated from the site questionnaire.
Calculate your project

05 / Field photos

Equipment
in the field.

Photos from sites: modules, controls and piping of the heat station.

05

06 / Turnkey packages

A ready system
with a clear price.

Presentation-based estimate. Final configuration depends on the heat balance, hot water and number of loops.

06

Transport, fuel storage and regional costs are confirmed from the project questionnaire.

07 / Comparison

TermaRON compared
with other solutions

Parameter
TermaRON
Electric boiler
Gas boiler
Coal boiler
Diesel boiler
Running costs
~3.6–5.3 RUB/kWhThree times cheaper than an electric boiler and half the cost of diesel. Best where there is no gas.
~10.8–16 RUB/kWh
Only where a gas main is available.
Plus delivery, storage and ash removal.
~9.6 RUB/kWh
Permits required
None.
Under 30 kW of electrical capacity.
None. Standard grid connection.
Gas supply project, approvals and commissioning are required.
No explicit permits, but a flue and a separate room are needed for the boiler and coal.
No explicit permits, but fuel storage conditions are needed (a separate boiler room).
Maintenance
Minimal.
Once a year — pre-season preparation.
Periodic replacement/descaling of heating elements.
Regular.
Annual service of the burner, controls and flue.
Constant.
Daily coal loading, ash removal, flue cleaning.
Constant supervision of the burner, soot cleaning, fuel purchasing and filtering.
Safety
Very high.
No gas, pressure or open flame. Fully safe.
High.
No gas, but high voltage (leakage risk).
Medium.
Risk of gas leak and explosion, ventilation and automation required.
Low.
Risk of carbon monoxide poisoning and fire, smoke and soot.
Medium.
Flammable fuel, fire risk, exhaust fumes and odour.
Installation complexity
Low.
Only a grid connection is needed; no flue required.
Low. Grid connection; no flue needed.
High.
Gas pipeline, a separate room, building codes.
Medium.
Flue, boiler room, coal storage.
High.
A separate place for the tank, a flue and safety measures are required.
Additional costs
Minimal.
Periodic inspection.
Electricity,
maintenance.
Gas storage and delivery costs,
maintenance.
Coal,
delivery, storage, ash removal.
Fuel,
transport, storage.

Cost of 1 kWh of heat at business tariffs, October 2026, Moscow and Moscow region: electricity 10.8–16 RUB/kWh incl. VAT, diesel 86.7 RUB/l (Rosstat), diesel boiler efficiency 90%. An exact calculation is made from the site questionnaire.

Calculate your project

08 / Benefits

Value for everyone
responsible for heat.

TermaRON combines advanced technology with practical returns. Choose who you are — we will show what matters.

08
01

Lower costs

On large sites, savings run to hundreds of thousands a year — lowering the cost of your services and products.

02

Fast roll-out

No gas facilities to register and no boiler-room operators to hire. Quick installation with no gas-service approvals.

03

Less grid load

A module draws three times less than a standard electric boiler — no need to expand the supply or add a transformer.

04

Reliability

No combustible fuel, so no supply disruptions. The system holds temperature on schedule automatically.

Why it is reliable

15+ yearsof the technology in service
100+sites
36 monthsmodule warranty

09 / Trust

Technology
proven by time.

With ATP-TermaRON you get a patented technology and a team that supports your project from calculation to commissioning.

09
01

25+ years of R&D

The developer of TermaRON technology has worked in energy saving since 1998.

02

Patent and awards

Utility model patent. Finalist of the “Small Energy — Big Achievements” award (2018).

03

Geography

100+ sites from Adler to Yakutsk: homes, residential complexes, hotels and plants.

04

Certification

The equipment has been tested and complies with GOST and fire-safety standards.

05

Clients and partners

Developers, management companies, industrial and municipal sites.

06

Engineering team

Engineers and the authors of the technology support the project at every stage.

10 / FAQ

Frequently asked
questions.

Did not find your answer? Leave a request — an engineer will reply and calculate your site.

Ask a question ↗
01Do I need permits to install it?

No special permits are required. Modules up to 100 kW are not classed as hazardous facilities and need no gas-service approvals. Installation is standard electrical work under the electrical installation code. If your power demand grows, you only agree it with the utility, as for any electrical equipment. We provide all technical documentation.

02How safe is the technology?

TermaRON creates no high pressure, uses no gas and has no open flame. Heating happens without combustion, so the typical risks of gas and solid-fuel boilers are absent.

03What maintenance is needed?

Minimal: usually one scheduled check a year before the season. No burner cleaning, fuel deliveries or complex servicing. A service engineer performs the check.

04Can it supply hot water?

Yes. The system handles both heating and hot water and works with an indirect hot-water tank and underfloor heating. We choose the connection scheme for your site.

05What about warranty and service life?

Warranty is 36 months on the module and 12 months on the ZONT controller. Design service life is 20+ years, proven on sites with harsh climates.

11 / Economics

How much heat
does your site need?

Choose the area to see a power, consumption and payback estimate.

What you replace
20 0001 000 000
505 000
Monthly saving187 600 ₽
Equipment package733 000 ₽ATM-TERM / 3F
Payback3.9 mo.
Payback scale0 12 mo.

Illustrative estimate: replacing an electric boiler, the new bill is about 33% of the current one; diesel, about 50%; an LPG tank, about 90%. We calculate the exact heat balance and payback free of charge from your site questionnaire.

Transport, fuel storage and regional costs are confirmed from the project questionnaire.

A

ATMTERM / 2026

Get an exact estimate

An ATMTERM engineer will calculate the heat balance and system configuration.